Home > Products > Nitrogen Evaporator > Well-Plate Nitrogen Evaporators

Dual Heating
Two Technologies

Well Plate Evaporators

Models in the well-plate range
0

Largest well format supported
0

Max. operating temperature
0 °C

Nitrogen Evaporators · Well-Plate Range

Well-Plate Nitrogen Evaporators

Three models engineered for 96-well microplate sample concentration. Takahe is the only Indian manufacturer of world-class well plate evaporators — offering open and closed-lid formats, single and dual plate capacity. Designed, manufactured, and quality-tested in Navi Mumbai since 2003.

Vortex Gas Blowdown technology. All Takahe well-plate nitrogen evaporators use vortexed nitrogen, which enlarges the evaporation surface area and equalises gas pressure across every position — delivering fast, uniform evaporation and lower gas consumption than conventional blowdown. 
Read the full explanation on the nitrogen evaporators hub →

Well-Plate · Flagship

Duo-eVap

Open-format 96-well plate evaporator - dual heated nitrogen, single plate

Autoclavable needles

Dual heating

Flagship


96-well plate
0

well formats
0 - 384
upper/lower
0 /75°C

The Duo-eVap is Takahe’s flagship well plate nitrogen evaporator for diagnostic and research laboratories processing 96-well microplates under a fume hood. Its dual-heating design directs heated nitrogen from both above and below each well simultaneously for faster, more uniform evaporation than single-surface methods.

The adjustable bay accommodates plates from 24 to 384 wells, plus 12 mm test tubes with optional accessories. Needles are visible during the run, removable, and autoclavable – simplifying batch-to-batch decontamination.

Distinctive features

Well-Plate · High throughput

Dual Duo-eVap

High-throughput dual 96-well plate evaporator — two plates simultaneously

192 samples

Two plates

Dual heating


well - plates
0

samples per run
0
well formats
0 -384

The Dual Duo-eVap processes two standard 96-well plates simultaneously i.e. 192 samples per run. It best meets the needs of a high-throughput laboratory processing two well plates by the same method in a single batch.

Both plate bays share the same gas, temperature, and flow settings — optimal for CRO and diagnostic labs running identical study batches side by side. Custom configurations with individual bay control are available on request.

Distinctive features

Well-Plate · Closed-lid

SpeedoVap 96WP

Closed-lid 96-well plate evaporator — microprocessor controlled, no fume hood required

No hood needed

Closed lid

Dry block


96-well plate
0

dry block max
0 °C
LPM gas flow
0

The SpeedoVap 96WP is a closed-lid 96-well plate evaporator with a microprocessor-controlled dry block and programmable timer. Set the block temperature and run time; nitrogen flows through nozzles into each well and shuts off automatically with an audio alarm when complete.

The closed lid encloses the bay entirely, and an in-built exhaust vent means no fume hood is required. Best suited to labs with a fixed 96-well workflow and no need to run vials or alternative plate formats alongside.

Note: concentrated acid solutions may be used only with a highly efficient exhaust system in place — consult Takahe before use.

Distinctive features

Low Volume · Dry heat

SpeedoVap Dry Block

Dry heat nitrogen evaporator — no water bath, minimal contamination risk

No water bath

Low contamination

15 samples


Max. samples
0

Max Volume
0 ml
LPM gas flow
0

block temp
0 °C

The SpeedoVap Dry Block replaces the water bath with a precision aluminium dry-heat block — the preferred choice where water-borne cross-contamination is a concern. Low contamination risk makes it well suited to sensitive clinical, forensic, and trace-analysis workflows.

Processes up to 15 samples simultaneously using the same nitrogen blowdown principle as the rest of the SpeedoVap range, with three independently controlled manifolds and full timer control.

Distinctive features

Request a quote

Request a demo

Full specifications

Max. samples (per batch)15
Max. sample volume15 mL
Block supplied1 block (Eppendorf / RIA / Tarson)
Heat block temperatureAmbient to 80°C
Timer range1 min to 9 hrs 50 min / indefinite
Gas inlet pressureMin. 70 psi / Max. 100 psi
Gas flow required45 LPM
Gas control3 independent manifolds
TechnologyVortex Gas Blowdown
Power requirements230 VAC / 50 Hz
Net weight18 kg
Shipping weight25 kg

Common to all low volume models

Compare all models in this range

Specification
Duo-eVap
Dual Duo-eVap
SpeedoVap 96WP
FormatOpen (fume hood)Open (fume hood)Closed lid
Well plate capacity1 × 96-well2 × 96-well1 × 96-well
Formats supported24–384 / tubes24–384 / tubes96 (1000/2000 µL)
HeatingHeated N₂ (upper + lower)Heated N₂ (upper + lower)Dry block (ambient–70°C)
Operating temperature60°C upper · 75°C lower60°C upper · 75°C lowerAmbient to 70°C
Gas flow rate20–100 LPM × 220–100 LPM × 2170 LPM
Autoclavable needlesYesYes
Dimensions (W × D × H)   
Net weight / Shipping weight 25 kg28 kg9.5 kg

Compare all models in this range

Model Max samples Max volume Heating Gas flow Best for
SpeedoVap LV 50 30 mL Water bath 150 LPM Pharma, pesticide, clinical, food labs
SpeedoVap LX 30 / 50 30 mL Water bath 90–150 LPM Small labs, cost-sensitive budgets
Min-eVap (MV) 15 15 mL Water bath 45 LPM Education, food QC, low workload
SpeedoVap Dry Block 15 15 mL Dry heat block 45 LPM Contamination-sensitive, clinical, forensic

Compare all models in this range

Model Max samples Max volume Heating Gas flow Best for
SpeedoVap LV 50 30 mL Water bath 150 LPM Pharma, pesticide, clinical, food labs
SpeedoVap LX 30 / 50 30 mL Water bath 90–150 LPM Small labs, cost-sensitive budgets
Min-eVap (MV) 15 15 mL Water bath 45 LPM Education, food QC, low workload
SpeedoVap Dry Block 15 15 mL Dry heat block 45 LPM Contamination-sensitive, clinical, forensic

Applications

Where this range is used

Clinical Research — BA/BE

High-throughput plate concentration for Phase II/IV pharmacokinetic studies at CROs. The Dual Duo-eVap runs 192 samples per batch.

Duo-eVap · Dual Duo-eVap

Diagnostics & DNA Testing

Plate-format sample preparation for diagnostic DNA testing and toxicology screens needing reproducible, uniform evaporation.

Duo-eVap · SpeedoVap 96WP

Pharmaceutical DMPK & Discovery

DMPK and discovery laboratories with high plate volumes — dual-plate throughput keeps pace with screening campaigns.

Dual Duo-eVap

Frequently asked questions

Well-Plate Nitrogen evaporator questions answered

Takahe is the only Indian manufacturer offering both formats – open for flexibility and method development, closed for containment and bench-top operation without a hood. That means spares in India, service engineers across the country, and no import wait when a needle head needs replacing.

Needle depth is adjustable, so gas hits the liquid surface directly – the biggest single factor in dry-down speed. The bay drops or lifts to take any plate from 24 to 384 wells, plus tubes and vials. Needles stay visible through the run, so the analyst stops at “just dry” instead of over-drying volatile analytes. Removable, autoclavable needles make decontamination straightforward.

Yes – the Duo-eVap and Dual Duo-eVap are open format and must run inside a fume hood. Front-panel controls are laid out for visibility through the sash. No fume-hood in your lab? Takahe can provide one specifically to fit the Duo-eVAP

Standard 96-well and deep-well plates are the everyday application, including 1000 µL and 2000 µL depths. The adjustable bay also takes 24, 48 and 384-well plates, and with optional accessories, 12 mm test tubes, HPLC vials and RIA vials. Aqueous and organic solvents both supported. One instrument covers your plate work and your vial methods.

Duo-eVap: an open, height-adjustable bay with a needle manifold delivering dual sided heated nitrogen.
SpeedoVap 96WP: a microprocessor-controlled aluminium dry block, ambient to 70 °C, sealed under a closed lid with in-built exhaust and duct hose.

Choose the Duo-eVap for format flexibility, method development, mixed plate-and-vial workflows, thermally sensitive analytes, and labs with hood access. Choose the SpeedoVap 96WP for a fixed 96-well routine, unattended walk-away operation with timer and auto shut-off, and benches without a fume hood. Note the 96WP is 96-well only — no 24, 48 or 384-well plates, no vials.

Yes. The Dual Duo-eVap runs two standard 96-well plates simultaneously — 192 samples per batch. Both bays share gas, temperature and flow settings by default, which suits CRO and diagnostic labs running identical study batches side by side. Individual bay control is available as a custom configuration on request.

On the Duo-eVap, the gas manifold head lifts off and the needles are individually removable and autoclavable – they can also be sonicated or replaced if damaged. Because the wells stay visible and vapour is drawn straight to the hood, there is no enclosed chamber for residue to accumulate in. A clear, documented answer when an auditor asks about carryover.

Both models handle aqueous and organic solvents as standard. Concentrated acid solutions require a highly efficient exhaust system in place – please consult Takahe before use so we can confirm suitability for your method. Anti-corrosion and PTFE-coated needle options are available on request for aggressive chemistries.

The Duo-eVap draws 100 LPM per channel; the SpeedoVap 96WP runs at 170 LPM. Cylinder supply works, but at plate-format throughput most labs find the changeover frequency and cost add up quickly. Takahe manufactures nitrogen generators sized for exactly this duty — ask us to specify one alongside your evaporator.

Not sure which model fits your lab?

Tell us your sample volumes, batch size, tube format, and application — our team will recommend the correct low volume model the same working day.

Rest of the range

Other nitrogen evaporator categories

High volume

High Volume Evaporators

30 mL–200 mL vessels, 8–15 samples, with optional automatic end-point detection.

Low volume

Low Volume Evaporators

1.5 mL–30 mL tubes, up to 50 samples — SpeedoVap LV, LX, Min-eVap, Dry Block.

Large format

Large Format Evaporators

100 to 210 samples per batch for BA/BE clinical-scale studies.

Low Volume Flagship

Most installed

SpeedoVap LV

Automated low volume sample concentrator — up to 50 samples per batch


Max. samples
0

Max Volume
0 ml
LPM gas flow
0

Independent manifolds
0

The SpeedoVap LV (SVLV) is Takahe’s most widely installed nitrogen evaporator — an automated, high-speed low volume concentrator handling up to 50 samples per batch using interchangeable racks for tube formats from 1.5 mL to 30 mL.

Gas can be activated selectively on any of five independent manifolds, so different sample types can run simultaneously. Widely used for solvent evaporation in pharmaceutical drug analysis and pesticide extract preparation.

Distinctive features

Max. samples (per batch)50
Max. sample volume30 mL
Water bath temperatureAmbient to 80°C (90°C on request)
Timer range1 min to 9 hrs 50 min / indefinite
Gas inlet pressure100 psi
Gas flow required150 LPM
Gas control5 independent manifolds
TechnologyVortex Gas Blowdown
Dimensions (W × D × H)63.5 × 35.6 × 33.7 cm
Net weight18 kg
Shipping weight25 kg
Compatible tubes & vials
VolumeTube / vial type
2 mLFlip/screw cap micro-centrifuge, Eppendorf
3 mL10 × 75
4 mL12 × 75 / Ria vials
4 mL14 × 45 screw top vial
12 mL16 × 100
15 mL17 × 125
30 mL20 × 150