Home > Products > Nitrogen Evaporator > Large Format Nitrogen Evaporators

210 samples. 250 lpm
One compact unit.

Large Format Evaporators

Models
0

Dual

Pressure Setting


Max N2 requirement
0 LPM

speX

rack compatible

Nitrogen Evaporators · Large Format Range

Nitrogen Evaporators — Large Format Range

The Bio-eVap range is Takahe’s large-format line for bioanalytical CROs and DMPK laboratories running Phase II and Phase IV clinical trials. Four models cover 100 to 210 sample positions — including India’s highest-capacity nitrogen evaporator — all using vortexed nitrogen for uniform evaporation across every position in a large array.

Vortex Gas Blowdown technology. All Takahe large format nitrogen evaporators use vortexed nitrogen, which enlarges the evaporation surface area and equalises gas pressure across every position — delivering fast, uniform evaporation and lower gas consumption than conventional blowdown. 

Read the full explanation on the nitrogen evaporators hub →

Large Format · Entry

Bio-eVap 100

Entry to large-format evaporation — 100 samples in a 10 × 10 matrix

Base model

100 samples

10 × 10


Max. samples
0

Max Volume
0 ml
LPM gas flow
0

The entry point to large-format nitrogen evaporation. The Bio-eVap 100 processes 100 samples in a 10 × 10 matrix — suited to CROs running medium-size Phase II study batches.

Individual manifold control allows partial batches to be run efficiently without wasting nitrogen.

Distinctive features

Large Format · Flagship

Bio-eVap 144 DP

Flagship dual-pressure model — 144 samples with contamination-free run initiation

Flagship

Dual Pressure

144 samples


Max. samples
0

12×12

matrix

LPM gas flow
0

Takahe’s flagship large-format model. The Dual Pressure option sets separate initial and operational nitrogen pressures at method start — eliminating contamination risk from excess gas pressure at run initiation. This is a unique feature not available on the LX model.

Removable nozzle tips allow sonication with no realignment, and a door-open sensor auto-stops the run if the door is opened mid-cycle.

Distinctive features

Large Format · Budget 144

Bio-eVap LX

Cost-effective 144-position model — same throughput, simplified gas control

Cost-effective

3 X 4 manifold control

Single switch


Max. samples
0

3 × 4

manifold control

The cost-effective route to 144-sample throughput. The Bio-eVap LX shares the same 12 × 12 matrix and 220 LPM nitrogen efficiency as the DP — with simplified gas control: four manifold rows operated by a single switch make setup fast and straightforward.

For labs where Dual Pressure is not required, the LX offers equivalent throughput at a lower acquisition cost.

Distinctive features

Large Format · Ultra high capacity

Bio-eVap UHC 210

India's highest-capacity nitrogen evaporator — 210 samples at just 250 LPM

New Launch

210 samples

Highest in India


matrix
15 x 0
LPM max
0

RIA vials
0 mL

India’s highest-capacity nitrogen evaporator. The Bio-eVap UHC (Ultra High Capacity) processes 210 samples per batch at a maximum of 250 LPM — well below the 400 LPM required by competing systems of equivalent capacity.

Vortexing distributes nitrogen uniformly across all 210 positions, eliminating batch-to-batch variability at this scale. Designed for 4 mL RIA vials — the standard format for bioanalytical pharmacokinetic studies.

Distinctive features

Specifications for all Large Format Bio-eVap Series Nitrogen Evaporators

Specification
Bio-eVap 100
Bio-eVap 144 DP
BVLX
Bio-eVap UHC
Max. samples (per batch)100144144210
Max. sample volume15 mL12 mL12 mL4 mL
Set-up Matrix10 × 1012 × 1212 × 1215 × 14
Water bath temperatureAmbient to 80°CAmbient to 80°CAmbient to 80°CAmbient to 80°C
Timer range1 min to 9 hrs 50 min / indefinite1 min to 9 hrs 50 min / indefinite1 min to 9 hrs 50 min / indefinite1 min to 9 hrs 50 min / indefinite
Gas inlet pressure100 psi100 psi100 psi100 psi
N2 Gas flow required180 lpm240 lpm240 lpm300 lpm
Gas control Manifolds)101247
TechnologyVortexing Gas BlowdownVortexing Gas BlowdownVortexing Gas BlowdownVortexing Gas Blowdown
SPE rack compatibilityNAspeX 144speX 144speX 210 UHC
Dimensions (W × D × H)39 x 71 x 25 cm58 x 57 x 30 cm58 x 57 x 30 cm58 x 57 x 30 cm
Net weight17 kg18.5 kg18.5 kg16.0 kg
Shipping Weight30 kg35 kg35 kg35 kg

CompatibleTube and Vials

Volume
Tube / Vial Type
BV 100
BV DP
BV LX
UHC
2 mL Flip/screw cap micro-centrifuge, Eppendorf
3 mL 10 × 75
4 mL 12 × 75 / RIA vials
12 mL 16 × 100

Nitrogen Evaporators series - combined specifications

ParameterSpeedovap LVSpeedovap LXMin-eVapSpeedovap Dry Block
Max. samples (per batch)5030 / 501515
Max. sample volume30 mL30 mL15 mL15 mL
Water bath temperatureAmbient to 80°C (90°C on request)Ambient to 80°CAmbient to 80°C (90°C on request)Ambient to 80°C
Timer range1 min to 9 hrs 50 min / indefinite1 min to 10 hours / indefinite1 min to 9 hrs 50 min / indefinite1 min to 9 hrs 50 min / indefinite
Gas inlet pressure100 psiMin. 70 psi / Max. 100 psi100 psiMin. 70 psi / Max. 100 psi
Gas flow required150 LPM90 LPM / 150 LPM45 LPM45 LPM
Gas control5 independent manifolds3 / 5 Independent Manifolds3 independent manifolds3 independent manifolds
TechnologyVortex Gas BlowdownVortex Gas BlowdownVortex Gas BlowdownVortex Gas Blowdown
Dimensions (W × D × H)63.5 × 35.6 × 33.7 cm63.5 × 35.6 × 33.7 cm40 × 36 × 28 cm63.5 × 35.6 × 33.7 cm
Net weight18 kg18 kg9.5 kg18 kg
Shipping Weight25 kg25 kg15 kg25 kg

Common to all Bio-eVap models

Compare all models in this range

Specification Bio-eVap 100 Bio-eVap 144 DP Bio-eVap LX Bio-eVap UHC
Max samples per batch 100 144 144 210
Matrix 10 × 10 12 × 12 12 × 12 15 × 14
Max sample volume 15 mL 12 mL 12 mL 4 mL (RIA)
Gas flow required 200 LPM 220 LPM 220 LPM 250 LPM max
Gas control Individual Individual · Dual Pressure 4 manifolds · 1 switch 2 manifolds · 1 switch
SPE rack compatibility NA speX 144 speX 144 speX 210 UHC
Net weight 17 kg 18.5 kg 18.5 kg 20.5 kg
Best for Phase II · mid CROs Phase IV · compliance Phase IV · cost conscious Largest batches

Applications

Where this range is used

Clinical Research — BA/BE Studies

High-throughput concentration for Phase II and IV pharmacokinetic studies. 100 to 210 samples processed per batch at bioanalytical CROs.

Bio-eVap 144 DP · UHC 210

Contract Research Organisations

CRO bioanalytical labs running multiple batches daily benefit from rack interoperability with speX SPE — measurable productivity and compliance gains.

Bio-eVap 144 DP · LX

DMPK & Discovery Research

Drug metabolism and pharmacokinetics labs needing uniform, reproducible evaporation across large sample arrays for GLP-compliant work.

Bio-eVap 100 · 144 DP

Frequently asked questions

Large Format Nitrogen evaporator questions answered

Both share the same 12 × 12 matrix, 220 LPM gas consumption, and vortexed nitrogen blowdown. The 144 DP adds Dual Pressure — separate initial and operational pressures set at method start, eliminating contamination risk at run initiation. The LX has four manifolds on a single switch — simpler and lower cost. Choose DP for full-compliance workflows; choose LX where Dual Pressure is not required.

At run start, nozzle tips may carry residual liquid. Applying full operational pressure immediately can cause a brief gas burst that cross-contaminates adjacent samples. Dual Pressure sets a lower initial pressure that transitions automatically to operational pressure once steady-state flow is established — eliminating that risk without operator intervention. It is exclusive to the Bio-eVap 144 DP.

Competing large-format evaporators compensate for uneven gas distribution by increasing total flow. Vortexing distributes nitrogen efficiently from the outset, so no excess is needed — the Bio-eVap UHC achieves 210-sample throughput at 250 LPM maximum, roughly 37% less than competing systems.

The collection racks of the corresponding speX SPE system fit directly into the Bio-eVap, and evaporation racks fit back into the SPE system — no decanting, no relabelling. Bio-eVap 144 DP and LX ⇄ speX 144; Bio-eVap UHC ⇄ speX 210. This removes 20–30 minutes of technician time per batch and a critical contamination-risk point.

Not sure which model fits your lab?

Tell us your sample volumes, batch size, tube format, and application — our team will recommend the correct low volume model the same working day.

Rest of the range

Other nitrogen evaporator categories

Low Volume

15 to 50 samples – The most widely used solution across diverse industries

High Volume Evaporators

30 mL–200 mL vessels, 8–15 samples, with optional automatic end-point detection.

Well-Plate Evaporators

96-well microplate format — single, dual, and closed-lid models.

Low Volume Flagship

Most installed

SpeedoVap LV

Automated low volume sample concentrator — up to 50 samples per batch


Max. samples
0

Max Volume
0 ml
LPM gas flow
0

Independent manifolds
0

The SpeedoVap LV (SVLV) is Takahe’s most widely installed nitrogen evaporator — an automated, high-speed low volume concentrator handling up to 50 samples per batch using interchangeable racks for tube formats from 1.5 mL to 30 mL.

Gas can be activated selectively on any of five independent manifolds, so different sample types can run simultaneously. Widely used for solvent evaporation in pharmaceutical drug analysis and pesticide extract preparation.

Distinctive features

Max. samples (per batch)50
Max. sample volume30 mL
Water bath temperatureAmbient to 80°C (90°C on request)
Timer range1 min to 9 hrs 50 min / indefinite
Gas inlet pressure100 psi
Gas flow required150 LPM
Gas control5 independent manifolds
TechnologyVortex Gas Blowdown
Dimensions (W × D × H)63.5 × 35.6 × 33.7 cm
Net weight18 kg
Shipping weight25 kg
Compatible tubes & vials
VolumeTube / vial type
2 mLFlip/screw cap micro-centrifuge, Eppendorf
3 mL10 × 75
4 mL12 × 75 / Ria vials
4 mL14 × 45 screw top vial
12 mL16 × 100
15 mL17 × 125
30 mL20 × 150

Request a quote

Request a demo

Add to your nitrogen evaporator

Accessories and other instruments